Vaillant aroTHERM Heat Pump Error Codes

Complete diagnostic guide for Vaillant aroTHERM heat pumps in the United Kingdom.

Water Pressure and Flow Problems

Error codes for Vaillant aroTHERM heat pumps related to water pressure, flow and heating circuit problems.

Error CodeMeaningPossible CausesSolutions
F.022Water pressure too low
  • Too little water in heating system
  • Water loss due to leakage
  • Bleeding problems in system
  • Defective expansion vessel
  • Fill heating system with water to recommended pressure (approx. 1.5-2.0 bar)
  • Check system for leaks and repair
  • Bleed heating circuit completely
  • Check expansion vessel and replace if necessary
  • Check pressure switch and pressure gauge
  • Contact qualified service if problem persists
F.073Error: Water pressure sensor
  • Connection to water pressure sensor interrupted
  • Short circuit in sensor or wiring
  • Defective water pressure sensor
  • Loose or corroded connectors
  • Check wiring to water pressure sensor for damage
  • Check connectors for proper connection and corrosion
  • Inspect sensor for visible damage
  • Test water pressure sensor with multimeter
  • Replace sensor if defective
  • Restart system after repair
F.532Building circuit: Flow too low
  • Heating circuit not completely bled
  • Dirt filter in return line blocked or missing
  • Water shortage in system
  • Pressure loss in heating circuit too high
  • Pump wiring defective
  • Pump faulty or blocked
  • Bleed heating circuit completely
  • Clean or replace dirt filter in return line
  • Check water pressure in system and fill
  • Check flow rate at all radiators/valves
  • Check pump wiring for proper connection
  • Test pump for blockage or defect
  • Replace pump if necessary
  • Check system pressure and flow after repair

Fan and Ventilator Errors

Error codes for Vaillant aroTHERM heat pumps related to fan and airflow problems.

Error CodeMeaningPossible CausesSolutions
F.037Fan error
  • Obstruction in device airflow
  • Fan motor defective or not connected
  • Connection between main board and fan board damaged or interrupted
  • Blocked or contaminated fan blades
  • Defective fan board
  • Check airflow for obstructions, contamination or blockages
  • Check fan blades for contamination or damage and clean
  • Check wiring between main board and fan board for damage
  • Check connectors for proper connection
  • Test fan motor function
  • Replace fan board or motor if defective
  • Restart device after repair

Sensor and Probe Errors

Error codes for Vaillant aroTHERM heat pumps related to temperature sensor and probe problems.

Error CodeMeaningPossible CausesSolutions
F.514Probe error: Compressor inlet temperature
  • Sensor defective
  • Sensor not properly connected to main board
  • Interrupted or damaged connection
  • Short circuit in sensor or wiring
  • Check wiring to sensor for damage
  • Check connector for proper connection
  • Test sensor with multimeter
  • Inspect sensor for visible damage
  • Replace sensor if defective
  • Restart system after repair
F.517Probe error: Compressor outlet temperature
  • Sensor defective
  • Sensor not properly connected to main board
  • Interrupted or damaged connection
  • Short circuit in sensor or wiring
  • Check wiring to sensor for damage
  • Check connector for proper connection
  • Test sensor with multimeter
  • Inspect sensor for visible damage
  • Replace sensor if defective
  • Restart system after repair
F.519Probe error: Return temperature
  • Sensor defective
  • Sensor not properly connected to main board
  • Interrupted or damaged connection
  • Short circuit in sensor or wiring
  • Check wiring to sensor for damage
  • Check connector for proper connection
  • Test sensor with multimeter
  • Inspect sensor for visible damage
  • Replace sensor if defective
  • Restart system after repair
F.520Probe error: Flow temperature
  • Sensor defective
  • Sensor not properly connected to main board
  • Interrupted or damaged connection
  • Short circuit in sensor or wiring
  • Check wiring to sensor for damage
  • Check connector for proper connection
  • Test sensor with multimeter
  • Inspect sensor for visible damage
  • Replace sensor if defective
  • Restart system after repair
F.523Probe error: VF1
  • Connection to temperature probe VF1 interrupted
  • Short circuit in sensor or wiring
  • Sensor defective
  • Loose or corroded connector
  • Check wiring to temperature probe VF1 for damage
  • Check connector for proper connection and corrosion
  • Inspect sensor for visible damage
  • Test sensor with multimeter
  • Replace sensor if defective
  • Restart system after repair
F.526Probe error: EEV ambient circuit temperature
  • Sensor defective
  • Sensor not properly connected to main board
  • Interrupted or damaged connection
  • Short circuit in sensor or wiring
  • Check wiring to sensor for damage
  • Check connector for proper connection
  • Test sensor with multimeter
  • Inspect sensor for visible damage
  • Replace sensor if defective
  • Restart system after repair

System and Configuration Errors

Error codes for Vaillant aroTHERM heat pumps related to system errors, configuration problems and component errors.

Error CodeMeaningPossible CausesSolutions
F.042Error: Coding resistor
  • Device coding resistor defective or missing
  • Coding resistor value outside permissible range
  • Connector X25 not connected or incorrectly connected
  • Damaged circuit board
  • Check connector X25 for proper connection
  • Test coding resistor for correct value and function
  • Measure resistor value with multimeter and compare with specification
  • Replace coding resistor if defective
  • Check circuit board for damage
  • Restart device after repair
F.086Floor thermostat has opened
  • Floor temperature too high
  • Flow rate in heating circuit too low
  • Underfloor heating circuit is closed
  • Defective floor thermostat
  • Check floor temperature and reduce if necessary
  • Increase flow rate in heating circuit
  • Open underfloor heating circuit and ensure flow
  • Check floor thermostat function
  • Replace floor thermostat if defective
  • Check system settings
F.103Error: Spare part recognition
  • Parameter "max. duration of power interruption" incorrectly set
  • Installed main board does not match device
  • Inverter does not match device
  • Incorrect firmware version
  • Check and correct parameter "max. duration of power interruption" in settings
  • Check main board for compatibility with device type
  • Check inverter for compatibility
  • Check firmware version and update if necessary
  • Install correct components if incompatible
  • Contact qualified service for diagnosis and repair
F.536Compressor outlet temperature too high
  • Refrigerant amount too low
  • Sensor defective or not properly connected
  • Premature expansion in liquid area of refrigerant circuit (charge loss)
  • Electronic expansion valve defective
  • Heat exchanger blocked
  • Check refrigerant amount and refill if necessary (only by qualified service)
  • Check temperature sensor for function and proper connection
  • Test electronic expansion valve function
  • Check heat exchanger for blockage and clean
  • Check refrigerant circuit for leaks
  • Contact qualified service for complex problems

Need More Help?

If you are experiencing problems with your Vaillant aroTHERM heat pump that are not covered by these error codes, or if the provided solutions do not resolve your issue, we recommend:

  • Consult your Vaillant aroTHERM heat pump user manual for model-specific information
  • Contact Vaillant customer service in the United Kingdom for technical support
  • Seek help from a qualified heat pump repair technician
  • Check warranty coverage if your heat pump is still under warranty