Octopus Energy Cosy 6 Heat Pump Problems & Solutions

Complete diagnostic guide for Octopus Energy Cosy 6 heat pumps in the United Kingdom.

Note

The Octopus Energy Cosy 6 heat pump uses an intelligent control system. Specific numeric error codes may not be visible on the display. Instead, problems are often indicated by symptoms and behavior of the heat pump. The following information is based on common problems and their solutions.

Temperature and Heating Problems

Common problems with temperature control and heating function in Octopus Energy Cosy 6 heat pumps.

ProblemDescriptionPossible CausesSolutions
Cold RadiatorsRadiators remain cold or do not get warm enough
  • Target temperature already reached
  • Weather compensation active
  • Temperature sensor incorrectly positioned
  • Heating circuit not fully bled
  • Low water pressure in system
  • Check if target temperature is reached - this is normal with weather compensation active
  • Check temperature sensor position - should not be near heat sources or draughts
  • Bleed heating circuit completely
  • Check water pressure in system (should be between 1.0-1.5 bar)
  • Check thermostat settings
  • Contact Octopus Energy Support if problem persists
Heat pump switches off before reaching desired temperatureThe heat pump stops heating before the desired temperature is reached
  • Temperature sensor incorrectly positioned
  • Temperature sensor near heat sources
  • Temperature sensor in draught
  • Problems with temperature control
  • Weather compensation active
  • Check temperature sensor position
  • Ensure sensor is not placed near heat sources (e.g. lights, appliances)
  • Ensure sensor is not in draught
  • Check temperature control
  • Check weather compensation settings
  • Reposition sensor if necessary
House is too warmThe heat pump heats the house beyond the desired temperature
  • Thermostat settings too high
  • Boost function activated
  • Weather compensation settings incorrect
  • Temperature sensor defective or incorrectly positioned
  • Check thermostat settings and reduce if necessary
  • Check if boost function is activated and deactivate it
  • Check weather compensation settings
  • Check temperature sensor function
  • Adjust settings if necessary

Visible Signs and Appearances

Normal appearances and signs that may occur with Octopus Energy Cosy 6 heat pumps.

ProblemDescriptionPossible CausesSolutions
Steam or smoke from heat pumpSteam or smoke is visible during operation
  • Normal defrost cycle
  • Condensation during operation
  • Weather conditions (cold weather)
  • Steam during defrost cycle is normal and not a cause for concern
  • Condensation may occur in cold weather - this is normal
  • If steam occurs continuously and is not related to defrost cycle, contact Octopus Energy Support
Ice formation on the back of the heat pumpIce forms on the outdoor unit of the heat pump
  • Normal defrost cycle
  • Cold weather conditions
  • Humidity in the air
  • Ice formation in cold weather is normal and part of the defrost cycle
  • The heat pump should automatically defrost
  • If ice does not defrost or forms continuously, contact Octopus Energy Support
  • Do not attempt to remove ice manually

System and Performance Problems

Problems with system performance and general functions of the Octopus Energy Cosy 6 heat pump.

ProblemDescriptionPossible CausesSolutions
Heat pump does not startThe heat pump does not respond or does not start
  • Power failure or power interruption
  • Fuse tripped
  • Main switch turned off
  • Electronic error
  • Problems with power supply
  • Check if power is available
  • Check fuses
  • Check main switch
  • Restart system
  • Contact Octopus Energy Support if problem persists
Unusual noisesThe heat pump makes unusual or loud noises
  • Normal operation (fan, compressor)
  • Contaminated or blocked components
  • Loose parts
  • Wear parts
  • Some noises are normal during normal operation
  • Check if components are blocked or contaminated
  • Contact Octopus Energy Support for very loud or unusual noises
  • Do not attempt to repair the heat pump yourself
Low water pressureWater pressure in heating system is too low
  • Water loss due to leakage
  • Bleeding problems
  • Defective expansion vessel
  • Normal evaporation over time
  • Check water pressure (should be between 1.0-1.5 bar)
  • Check system for leaks
  • Bleed heating circuit completely
  • Refill water if necessary
  • Check expansion vessel
  • Contact Octopus Energy Support if problem persists

Need More Help?

If you are experiencing problems with your Octopus Energy Cosy 6 heat pump that are not covered by this information, or if the provided solutions do not resolve your issue, we recommend:

  • Consult the official Octopus Energy support page for heat pumps
  • Contact Octopus Energy customer service in the United Kingdom:
  • Seek help from a qualified heat pump repair technician
  • Check warranty coverage if your heat pump is still under warranty